CircuitPython driver for the TI INA260 current and power sensor * Author(s): Bryan Siepert Implementation Notes ——————– Hardware: * INA260 Breakout Software and Dependencies: * Adafruit CircuitPython firmware for the supported boards: * https://github.com/adafruit/circuitpython/releases * Adafruit’s Bus Device library: https://github.com/adafruit/Adafruit_CircuitPython_BusDevice * Adafruit’s Register library: https://github.com/adafruit/Adafruit_CircuitPython_Register

class adafruit_ina260.AveragingCount

Options for averaging_count

AveragingCount Number of measurements to average
AveragingCount.COUNT_1 1 (Default)
AveragingCount.COUNT_4 4
AveragingCount.COUNT_16 16
AveragingCount.COUNT_64 64
AveragingCount.COUNT_128 128
AveragingCount.COUNT_256 256
AveragingCount.COUNT_512 512
AveragingCount.COUNT_1024 1024
static get_averaging_count(avg_count)

Retrieve the number of measurements giving value read from register

class adafruit_ina260.ConversionTime

Options for current_conversion_time or voltage_conversion_time

ConversionTime Time
ConversionTime.TIME_140_us 140 us
ConversionTime.TIME_204_us 204 us
ConversionTime.TIME_332_us 332 us
ConversionTime.TIME_558_us 588 us
ConversionTime.TIME_1_1_ms 1.1 ms (Default)
ConversionTime.TIME_2_116_ms 2.116 ms
ConversionTime.TIME_4_156_ms 4.156 ms
ConversionTime.TIME_8_244_ms 8.244 ms
static get_seconds(time_enum)

Retrieve the time in seconds giving value read from register

class adafruit_ina260.INA260(i2c_bus, address=64)

Driver for the INA260 power and current sensor.

Parameters:
  • i2c_bus (I2C) – The I2C bus the INA260 is connected to.
  • address – The I2C device address for the sensor. Default is 0x40.
alert_function_flag

While only one Alert Function can be monitored at the ALERT pin at time, the Conversion Ready can also be enabled to assert the ALERT pin. Reading the Alert Function Flag following an alert allows the user to determine if the Alert Function was the source of the Alert.

When the Alert Latch Enable bit is set to Latch mode, the Alert Function Flag bit clears only when the Mask/Enable Register is read. When the Alert Latch Enable bit is set to Transparent mode, the Alert Function Flag bit is cleared following the next conversion that does not result in an Alert condition.

alert_latch_enable

Configures the latching feature of the ALERT pin and Alert Flag Bits.

alert_limit

The Alert Limit Register contains the value used to compare to the register selected in the Mask/Enable Register to determine if a limit has been exceeded. The format for this register will match the format of the register that is selected for comparison.

alert_polarity_bit

Active-high open collector when True, Active-low open collector when false (default).

averaging_count

The window size of the rolling average used in continuous mode

bus_voltage_over_voltage

Setting this bit high configures the ALERT pin to be asserted if the bus voltage measurement following a conversion exceeds the value programmed in the Alert Limit Register.

bus_voltage_under_voltage

Setting this bit high configures the ALERT pin to be asserted if the bus voltage measurement following a conversion drops below the value programmed in the Alert Limit Register.

conversion_ready

Setting this bit high configures the ALERT pin to be asserted when the Conversion Ready Flag, Bit 3, is asserted indicating that the device is ready for the next conversion.

current

The current (between V+ and V-) in mA

current_conversion_time

The conversion time taken for the current measurement

mask_enable

The Mask/Enable Register selects the function that is enabled to control the ALERT pin as well as how that pin functions. If multiple functions are enabled, the highest significant bit position Alert Function (D15-D11) takes priority and responds to the Alert Limit Register.

math_overflow_flag

This bit is set to 1 if an arithmetic operation resulted in an overflow error.

mode

The mode that the INA260 is operating in. Must be one of Mode.CONTINUOUS, Mode.TRIGGERED, or Mode.SHUTDOWN

overcurrent_limit

Setting this bit high configures the ALERT pin to be asserted if the current measurement following a conversion exceeds the value programmed in the Alert Limit Register.

power

The power being delivered to the load in mW

power_over_limit

Setting this bit high configures the ALERT pin to be asserted if the Power calculation made following a bus voltage measurement exceeds the value programmed in the Alert Limit Register.

reset_bit

Setting this bit t 1 generates a system reset. Reset all registers to default values.

revision_id

Device revision identification bits

under_current_limit

Setting this bit high configures the ALERT pin to be asserted if the current measurement following a conversion drops below the value programmed in the Alert Limit Register.

voltage

The bus voltage in V

voltage_conversion_time

The conversion time taken for the bus voltage measurement

class adafruit_ina260.Mode

Modes avaible to be set

Mode Description
Mode.CONTINUOUS Default: The sensor will continuously measure the bus voltage and shunt voltage across the shunt resistor to calculate power and current
Mode.TRIGGERED The sensor will immediately begin measuring and calculating current, bus voltage, and power. Re-set this mode to initiate another measurement
Mode.SHUTDOWN Shutdown the sensor, reducing the quiescent current and turning off current into the device inputs. Set another mode to re-enable